1,032 research outputs found

    Trends of mechanical consequences and modeling of a fibrous membrane around femoral hip prostheses

    Get PDF
    In the present study, the effects of a fibrous membrane between cement and bone in a femoral total hip replacement were investigated. The study involved the problem of modeling this fibrous membrane in finite-element analyses, and its global consequences for the load-transfer mechanism and its resulting stress patterns. A finite-element model was developed, suitable to describe nonlinear contact conditions in combination with nonlinear material properties of the fibrous membrane. The fibrous tissue layer was described as a highly compliant material with little resistance against tension and shear. The analysis showed that the load transfer mechanism from stem to bone changes drastically when such a membrane is present. These effects are predominantly caused by tensile loosening and slip at the interface, and are enhanced by the nonlinear membrane characteristics.\ud \ud Using parametric analysis, it was shown that these effects on the load-transfer mechanism cannot be described satisfactorily with linear elastic models.\ud \ud Most importantly, the fibrous tissue interposition causes excessive stress concentrations in bone and cement, and relatively high relative displacements between these materials

    Fixatie-concepten, ontwerp en materiaalkeuze voor de totale heupprothese

    Get PDF
    Bijdrage op de Consensus-bijeenkomst, vrijdag 9 oktober 1987 te Rotterdam

    Mathematical modeling of the knee

    Get PDF
    No abstract

    The law of adaptive bone remodeling : a case for crying Newton?

    Get PDF
    The biological mechanisms of strain-adaptive bone remodeling are largely unknown. Yet, several authors published algorithms to mimic this process, without prior validation of its premises. Biologists are sometimes confused by this seemingly irresponsible behavior. However, this kind of inductive investigation has a long tradition in physics, inspired by Newton. Depending on its predictive capacity, an algorithm can reveal information about the process it simulates and generate fruitful hypotheses about underlying mechanisms. This obviously requires comparison of its results to an experimental reality at some point in time. But as the algorithms tend to be complicated, it is not unreasonable that they are discussed in the literature already in their developmental phases

    Stress patterns, failure modes, and bone remodeling

    Get PDF
    No abstract

    Quantitative analysis of bone reactions to relative motions at implant-bone interfaces

    Get PDF
    Connective soft tissues at the interface between implants and bone, such as in human joint replacements, can endanger the stability of the implant fixation. The potential of an implant to generate interface bone resorption and form soft tissue depends on many variables, including mechanical ones. These mechanical factors can be expressed in terms of relative motions between bone and implant at the interface or deformation of the interfacial material.\ud \ud The purpose of this investigation was to determine if interface debonding and subsequent relative interface motions can be responsible for interface degradation and soft tissue interposition as seen in experiments and clinical results. A finite element computer program was augmented with a mathematical description of interface debonding, dependent on interface stress criteria, and soft tissue interface interposition, dependent on relative interface motions. Three simplified models of orthopaedic implants were constructed: a cortical bone screw for fracture fixation plates, a femoral resurfacing prosthesis and a straight stem model, cemented in a bone. The predicted computer configurations were compared with clinical observations. The computer results showed how interface disruption and fibrous tissue interposition interrelate and possibly enhance each other, whereby a progressive development of the soft tissue layer can occur.\ud \ud Around the cortical bone screw, the predicted resorption patterns were relatively large directly under the screw head and showed a pivot point in the opposite cortex. The resurfacing cup model predicted some fibrous tissue formation under the medial and lateral cup rim, whereby the medial layer developed first because of higher initial interface stresses. The straight stem model predicted initial interface failure at the proximal parts. After proximal resorption and fibrous tissue interposition, the medial interface was completely disrupted and developed an interface layer. The distal and mid lateral side maintained within the strength criterion.\ud \ud Although the applied models were relatively simple, the results showed reasonable qualitative agreement with resorption patterns found in clinical studies concerning bone screws and the resurfacing cup. The hypothesis that interface debonding and subsequent relative (micro)motions could be responsible for bone resorption and fibrous tissue propagation is thereby sustained by the results

    Biomechanics of artificial joints : the hip

    Get PDF
    No abstrac

    On some of the biomechanical aspects of the pelvic bone

    Get PDF
    • …
    corecore